Quality & Compliance

Uncompromising Standards, Engineered for Life

At Clean and Control, quality is not a retrospective checkpoint — it is engineered into every calculation, CAD layout, orbital weld, and qualification protocol. Guided by ISO 9001, ISO 14001, and ISO 45001, we deliver high-integrity turnkey facilities aligned with global regulatory mandates.
Team Photo Placeholder

Clean & Control Site Execution Team

Certified orbital welders, MEP site engineers, and cleanroom installation technicians on active pharmaceutical project sites.

Replace asset: /images/team/site-workers.webp

Safety Record

3 Million+ Safe Man-Hours

People Behind Precision

Our Workforce, Our Strength

Behind every validated cleanroom suite and sterile utility loop is a team of disciplined craftsmen, certified orbital welders, MEP supervisors, and QA/QC specialists. We believe that true engineering excellence begins with the hands, minds, and safety of our people on the ground.

Clean and Control enforces stringent Environment, Health, and Safety (EHS) governance across all project sites. With over 3 Million safe man-hours executed with zero lost-time incidents, our workers are empowered with world-class PPE, continuous safety training, and the authority to pause work whenever safety or quality standards are compromised.

Certified ASME BPE Orbital Welders

High-purity SS 316L fabrication with 100% borescope inspection and complete mill test traceability.

Daily EHS Toolbox Talks & Hazard Control

Mandatory pre-shift safety briefings, job safety analyses (JSA), and strict cleanroom gowning/hygiene compliance.

Full-Time QA/QC Site Engineers

Independent quality supervision on active sites ensuring zero coordination gaps and zero rework.

Policy Commitment

Clean & Control Quality Policy

Our formal declaration of quality excellence, regulatory adherence, and continuous improvement across all turnkey pharmaceutical installations.

Clean and Control Technologies Pvt Ltd — Quality Creed

“Clean and Control is committed to engineering, constructing, and validating high-precision pharmaceutical and biotech facilities that consistently surpass client expectations and comply rigorously with international cGMP, statutory, and regulatory mandates.”

We achieve this by upholding single-source turnkey accountability, executing zero-defect installations, deploying certified engineering personnel, and continuously improving our Quality Management System in accordance with ISO 9001, ISO 14001, and ISO 45001 standards.

01

Regulatory Rigor

Built-in compliance with US FDA 21 CFR Part 11, EU GMP Annex 1, WHO, and Schedule M.

02

Zero Defect Goal

Stringent quality controls from concept modeling and material verification to cleanroom commissioning.

03

Safety & Wellbeing

Safeguarding every technician and engineer through ISO 45001 certified occupational safety systems.

04

Data Integrity

ALCOA+ documentation practices embedded across DQ, IQ, OQ, and PQ qualification phases.

Accreditations

ISO Certified Standards

Our Quality Management System is independently assessed and certified by international accreditation bodies, ensuring end-to-end reliability for our clients.

ISO 9001:2015 Certificate — Clean and Control
ISO 9001:2015

Quality Management System (QMS)

Cert No: 305025080752Q · Valid to 06 Aug 2028

Ensures disciplined project governance, defect prevention, robust vendor selection, and customer satisfaction across turnkey pharmaceutical facility delivery.

ISO 14001:2015 Certificate — Clean and Control
ISO 14001:2015

Environmental Management System (EMS)

Cert No: 305025080753E · Valid to 06 Aug 2028

Minimizes ecological footprint through eco-friendly cleanroom HVAC design, optimal thermal efficiency, sustainable utility integration, and compliant effluent management.

ISO 45001:2018 Certificate — Clean and Control
ISO 45001:2018

Occupational Health & Safety (OH&S)

Cert No: 305025080754HS · Valid to 06 Aug 2028

Safeguards all site engineers and trade workers with rigorous hazard identification, risk assessments, height safety governance, and zero-accident policies.

QA / QC Methodology

Quality at Every Project Stage

How Clean and Control embeds verification, documentation, and quality governance from initial user requirements through commercial facility validation.

Stage 01Design Quality (DQ)

Inspection-Ready Concept & Detail Design

  • Process flow architecture & room classification layouts (ISO 5–8 / Grade A–D)
  • HVAC airflow cascades, room pressure differentials, and CFD air simulation
  • GAMP 5 risk assessments and 21 CFR Part 11 software categorization
Stage 02Material & Vendor Qualification

High-Purity Sourcing & FAT Verifications

  • Rigorous vendor audits and mill test certificate (MTC) verification
  • Positive Material Identification (PMI) on all SS 316L contact metallurgy
  • Factory Acceptance Testing (FAT) with comprehensive pre-shipment sign-offs
Stage 03Site Execution & Installation (IQ)

Precision Cleanroom Envelope & MEP Erection

  • Automated orbital welding with 100% video borescope inspection records
  • Airtight cleanroom partition and flush door ceiling envelope sealing
  • Ductwork pressure leakage testing conforming to SMACNA / DW144 standards
Stage 04Commissioning & Qualification (OQ)

Air Balancing & Utility System Operational Testing

  • HEPA/ULPA filter PAO integrity (DOP) testing and air velocity profiling
  • Non-viable particle counting, recovery rate, and airflow pattern visualization
  • High-purity WFI and Pure Steam loop thermal sanitization & passivation checks
Stage 05Validation & Handover (PQ)

Audit-Ready Protocols & Operational Handover

  • Comprehensive Traceability Matrix linking User Requirements (URS) to PQ
  • Complete ALCOA+ data turnover packages ready for US FDA / WHO inspectors
  • Hands-on operational training and ongoing life-cycle engineering support

Connect With Quality Leadership

Build with Confidence, Deliver with Precision.

Consult with Clean & Control's turnkey engineering and QA/QC leads to review your cleanroom specifications, regulatory roadmap, or validation protocols.